Need specific help? Leave a comment below with your error code or parameter question.

| Error Code | Meaning | Best Fix (From the Manual) | | :--- | :--- | :--- | | | Internal memory failure | Controller is fried. Replace it. No manual can fix hardware. | | P1 | Room probe faulty or shorted | Check probe wires at pins 4 & 5. Replace NTC probe. | | P2 | Evaporator probe faulty | Check probe wires at pins 7 & 8. Parameter P2P likely set to y (yes). | | HA | High Temperature Alarm | Door left open? Condenser dirty? Check ALu parameter. | | LA | Low Temperature Alarm | Too much cold air. Check ALL parameter. | | dA | Defrost Alarm | Defrost took longer than tdF . Evaporator iced up? | | EA | External alarm | A digital input (door switch) is triggered. | How to Perform a Factory Reset (The "Get Out of Jail Free" Card) If you bought used equipment or messed up Pr2 so badly that the compressor runs constantly, you need the reset function. The official manual lists this as a "Load Defaults" procedure. eliwell sb655 c manual best

Do not set tdF too high. If you set it to 60 minutes and have a small evaporator, the cabinet will turn into a sauna. Troubleshooting: No Manual? No Problem. If you have lost your physical manual, use this logic table for the most common errors on the SB655 C display: Need specific help